This test shall evaluate the safety performance of a battery in over-discharge situations. Safety risks during over-discharge include polarity reversal leading to oxidation of the anode current collector (Copper) and to plating on the cathode side. Even minor over-discharge can cause dendrite formation and ultimately short-circuiting.