Article 12 › 2
By 18 August 2024, the technical documentation referred to in Annex VIII shall: (a) demonstrate that the stationary battery energy storage systems are compliant with paragraph 1 and include evidence that they have been successfully tested for the safety parameters set out in Annex V, for which state-of-the-art testing methodologies shall be used. The safety parameters shall only apply in so far as a corresponding hazard exists for the stationary battery energy storage system in question when it is used under the conditions envisaged by the manufacturer; (b) include an assessment of possible safety hazards of the stationary battery energy storage system that are not addressed in Annex V; (c) include evidence that the hazards referred to in point (b) have been successfully mitigated and tested; state-of-the-art testing methodologies shall be used for such testing; (d) include mitigation instructions in case the identified hazards could occur, for example a fire or explosion. The technical documentation shall be reviewed if a battery is prepared for re-use, prepared for repurposing, remanufactured or repurposed.