(ii)
or, as an alternative to point (i), ensure that the process for battery replacement meets the criteria set out in (a); after 500 full charge cycles the battery must have in a fully charged state, a remaining capacity of at least 83 % of the rated capacity; the battery endurance in cycles achieves a minimum of 1 000 full charge cycles, and after 1 000 full charge cycles the battery must, in addition, have in a fully charged state, a remaining capacity of at least 80 % of the rated capacity; the device is at least dust tight and protected against immersion in water up to one meter depth for a minimum of 30 minutes.