manufacturers, importers or authorised representatives may provide the battery or batteries referred to in point (i)(a) only to professional repairers if manufacturers, importers or authorised representatives ensure that the following requirements are met: after 500 full charge cycles the battery has, in a fully charged state, a remaining capacity of at least 83 % of the rated capacity; the battery endurance in cycles achieves a minimum of 1 000 full charge cycles and after 1 000 full charge cycles the battery has, in a fully charged state, a remaining capacity of at least 80 % of the rated capacity; the device meets IP67 rating.