For the assessment of annual mean values via indicative measurements and, via fixed measurements for pollutants with a minimum data coverage below 80 %, Member States may apply random measurements instead of continuous measurements if they can demonstrate that the uncertainty, including the uncertainty due to random sampling, meets the required data quality objectives and minimum data coverage for indicative measurements. Such random sampling shall be evenly distributed over the year in order to avoid skewing of results. The uncertainty due to random sampling may be determined by the procedure laid down in ISO 11222 (2002) ‘Air Quality – Determination of the Uncertainty of the Time Average of Air Quality Measurements’.