3.
CONSTRUCTION SPECIFICATIONS 3.1. General The design shall be such that under steady-speed operating conditions the smoke chamber is filled with smoke of uniform opacity. 3.2. Smoke chamber and opacimeter casing 3.2.1. The impingement on the photoelectric cell of stray light due to internal reflections or diffusion effects shall be reduced to a minimum (e.g. by finishing internal surfaces in matt black and by a suitable general layout). 3.2.2. The optical characteristics shall be such that the combined effect of diffusion and reflection does not exceed one unit on the linear scale when the smoke chamber is filled with smoke having an absorption coefficient near 1 77 m-1. 3.3. Light source The light source shall be an incandescent lamp with a colour temperature in the range 2 800 to 3 250 ºK. 3.4. Receiver 3.4.1. The receiver shall consist of a photoelectric cell with a spectral response curve similar to the photopic curve of the human eye (maximum response in the range 550/570 nm ; less than 4 per cent of that maximum response below 430 nm and above 680 nm). 3.4.2. The construction of the electrical circuit, including the indicating dial, shall be such that the current output from the photoelectric cell is a linear function of the intensity of the light received over the operating-temperature range of the photoelectric cell. 3.5. Measuring scales 3.5.1. >PIC FILE= "T0010777"> - either by the method described in item 4 of this Annex ; or through correlation with another type of opacimeter for which the effective length is known. 3.5.2. The relationship between the 0-100 linear scale and the light absorption coefficient k is given by the formula >PIC FILE= "T0010778"> where N is a reading on the linear scale and k the corresponding value of the absorption coefficient. 3.5.3. The indicating dial of the opacimeter shall enable an absorption coefficient of 1 77 m-1 to be read with an accuracy of 0 7025 m-1. 3.6. Setting and testing of the measuring apparatus 3.6.1. The electrical circuit of the photoelectric cell and of the indicating dial shall be adjustable so that the pointer can be reset at zero when the light flux passes through the smoke chamber filled with clean air or through a chamber having identical characteristics. 3.6.2. >PIC FILE= "T0010779"> 3.6.3. An intermediate check shall be carried our by placing in the smoke chamber a screen representing a gas whose known light-absorption coefficient k, measured as described in item 3.5.1, is between 1 76 m-1 and 1 78 m-1. The value of k must be known to within 0 7025 m-1. The check consists in verifying that this value does not differ by more than 0 705 m-1 from that read on the opacimeter indicating dial when the screen is introduced between the source of light and the photoelectric cell. 3.7. Opacimeter response 3.7.1. The response time of the electrical measuring circuit, being the time necessary for the indicating dial to reach 90 per cent of full-scale deflection on removal of a screen fully obscuring the photoelectric cell, shall be 0 79 to 1 71 second. 3.7.2. The damping of the electrical measuring circuit shall be such that the initial overswing beyond the final steady reading after any momentary variation in input (e.g. the calibration screen) does not exceed 4 per cent of that reading in linear scale units. 3.7.3. The response time of the opacimeter which is due to physical phenomena in the smoke chamber is the time between the entry of the gas into the measuring apparatus and the complete filling of the smoke chamber ; it shall not exceed 0 74 second. 3.7.4. These provisions shall apply solely to opacimeters used to measure opacity under free acceleration. 3.8. Pressure of the gas to be measured and of scavenging air 3.8.1. The pressure of the exhaust gas in the smoke chamber shall not differ by more than 75 mm (water gauge) from the atmospheric pressure. 3.8.2. The variations in the pressure of the gas to be measured and of the scavenging air shall not cause the absorption coefficient to vary by more than 0 705 m-1 in the case of a gas having an absorption coefficient of 1 77 m-1. 3.8.3. The opacimeter shall be equipped with appropriate devices for measuring the pressure in the smoke chamber. 3.8.4. The limits of pressure variation of gas and scavenging air in the smoke chamber shall be indicated by the manufacturer of the apparatus. 3.9. Temperature of the gas to be measured 3.9.1. At every point in the smoke chamber the gas temperature at the instant of measurement shall be between 70 ºC and a maximum temperature, specified by the opacimeter manufacturer, such that the readings over this temperature range do not vary by more than 0 71 m-1 if the chamber is filled with a gas having an absorption coefficient of 1 77 m-1. 3.9.2. The opacimeter shall be equipped with appropriate devices for measuring the temperature in the smoke chamber.
← 2. · All articles · - →
Source: EUR-Lex (Cellar) · retrieved 2026-11-22 · Text as adopted (Official Journal); later amendments are not incorporated in this text.