4.

EFFECTIVE LENGTH "L" OF THE OPACIMETER 4.1. General 4.1.1. In some types of opacimeter the gas between the light source and the photoelectric cell, or between transparent parts protecting the source and the photoelectric cell, is not of constant opacity. In such cases the effective length L shall be that of a column of gas of uniform opacity which gives the same absorption of light as that obtained when the gas is admitted in a normal way into the opacimeter. 4.1.2. The effective length of the light path is obtained by comparing the reading N of the opacimeter operating normally with the reading No obtained with the opacimeter modified so that the test gas fills a well defined length Lo. 4.1.3. It will be necessary to take comparative readings in quick succession to determine the correction to be made for shifts of zero. 4.2. Method of assessment of L 4.2.1. The test gas shall be exhaust gas of constant opacity or a light-absorptive gas of a gravimetric density similar to that of the exhaust gas. 4.2.2. A column of length Lo of the opacimeter, which can be filled uniformly with the test gases, and the ends of which are substantially at right angles to the light path, shall be accurately determined. This length Lo shall be close to the presumed effective length of the opacimeter. 4.2.3. The mean temperature of the test gas in the smoke chamber shall be measured. 4.2.4. If necessary, an expansion tank of compact design and of sufficient capacity to damp the pulsations may be incorporated in the sampling line as near to the probe as possible. A cooler may also be fitted. The addition of the expansion tank and of the cooler must not unduly disturb the composition of the exhaust gas. 4.2.5. The test for determining the effective length shall consist of passing a sample of test gas alternately through the opacimeter operating normally and through the same apparatus modified as indicated in item 4.1.2. 4.2.5.1. The opacimeter readings shall be recorded continuously during the test with a recorder whose response time is equal to or shorter than that of the opacimeter. 4.2.5.2. With the opacimeter operating normally, the reading on the linear scale of opacity is N and that of the mean gas temperature expressed in Kelvin degrees is T. 4.2.5.3. With the known length Lo filled with the same test gas, the reading on the linear scale of opacity is No and that of the mean gas temperature expressed in Kelvin degrees is To. 4.2.6. The effective length will be >PIC FILE= "T0010780"> 4.2.7. The test shall be repeated with at least four test gases giving readings evenly spaced between the 20 and 80 on the linear scale. 4.2.8. The effective length L of the opacimeter will be the arithmetic mean of the effective lengths obtained as stated in item 4.6 with each of the gases.

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-22 · Text as adopted (Official Journal); later amendments are not incorporated in this text.