6.8.2.2.7. Tanks intended for the carriage of liquids having a vapour pressure of more than 110 kPa (1,1 bar) but not exceeding 175 kPa (1,75 bar) (absolute) at 50 °C shall have a safety valve set at not less than 150 kPa (1,5 bar) (gauge pressure) and which shall be fully open at a pressure not exceeding the test pressure; otherwise they shall conform to 6.8.2.2.8.