6.8.2.2.8. Tanks intended for the carriage of liquids having a vapour pressure of more than 175 kPa (1,75 bar) but not exceeding 300 kPa (3 bar) (absolute) at 50 °C shall have a safety valve set at not less than 300 kPa (3 bar) gauge pressure and which shall be fully open at a pressure not exceeding the test pressure; otherwise they shall be hermetically closed(95).