When waste waters from the cleaning of exhaust gases containing the polluting substances referred to in Annex IV are treated outside the incineration or co-incineration plant at a treatment plant intended only for the treatment of this sort of waste water, the emission limit values of Annex IV are to be applied at the point where the waste waters leave the treatment plant. If this off-site treatment plant is not only dedicated to treat waste water from incineration, the operator shall take the appropriate mass balance calculations, as provided for under paragraph 4(a), (b) and (c), in order to determine the emission levels in the final waste water discharge that can be attributed to the waste water arising from the cleaning of exhaust gases in order to check compliance with the emission limit values set out in Annex IV for the waste water stream from the exhaust gas cleaning process. Under no circumstances shall dilution of waste water take place for the purpose of complying with the emission limit values set in Annex IV.