3.
The following procedure is used for each of the pollutants given in Section 6.2.1 of Annex I (see Figure 2): | Let: | L = the natural logarithm of the limit value for the pollutant; χi = the natural logarithm of the measurement for the i-th engine of the sample; s = an estimate of the production standard deviation (after taking the natural logarithm of the measurements); n = the current sample number.