lexiara

2.7.6. NOx check within the control area

The NOx check within the control area shall be performed immediately upon completion of mode 13. The engine shall be conditioned at mode 13 for a period of three minutes before the start of the measurements. Three measurements shall be made at different locations within the control area, selected by the Technical Service (1). The time for each measurement shall be 2 minutes. The measurement procedure is identical to the NOx measurement on the 13-mode cycle, and shall be carried out in accordance with Sections 2.7.3, 2.7.5, and 4.1 of this Appendix, and Annex III, Appendix 4, Section 3. The calculation shall be carried out in accordance with Section 4.

· All articles ·