4.1. Determination of the diluted exhaust gas flow

The total diluted exhaust gas flow over the cycle (kg/test) shall be calculated from the measurement values over the cycle and the corresponding calibration data of the flow measurement device (V0 for PDP or KV for CFV, as determined in Annex III, Appendix 5, Section 2). The following formulae shall be applied, if the temperature of the diluted exhaust is kept constant over the cycle by using a heat exchanger (± 6 K for a PDP-CVS, ± 11 K for a CFV-CVS, see Annex V, Section 2.3). For the PDP-CVS system: MTOTW = 1,293 × V0 × Np × (pB – p1) × 273 / (101,3 × T) where: For the CFV-CVS system: MTOTW = 1,293 × t × Kv × pA / T0,5 where: If a system with flow compensation is used (i.e. without heat exchanger), the instantaneous mass emissions shall be calculated and integrated over the cycle. In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows: For the PDP-CVS system: MTOTW,i = 1,293 × V0 × Np,i × (pB – p1) × 273 / (101,3 × T) where: For the CFV-CVS system: MTOTW,i = 1,293 × Δti × Kv × pA / T0,5 where: If the total sample mass of particulates (MSAM) and gaseous pollutants exceeds 0,5 % of the total CVS flow (MTOTW), the CVS flow shall be corrected for MSAM or the particulate sample flow shall be returned to the CVS prior to the flow measuring device (PDP or CFV).