sec_4_2_3__para
The analytical balance used to determine the weights of all filters shall have a precision (standard deviation) of 20 μg and a resolution of 10 μg (1 digit = 10 μg). For filters less than 70 mm diameter, the precision and resolution shall be 2 μg and 1 μg, respectively.
← 4.2.3. Analytical balance · All articles · 4.3. Additional specifications for particulate measurement →