4.4. Calculation of the emission mass flow rates
The emission mass flow rates (g/h) for each mode shall be calculated as follows, assuming the exhaust gas density to be 1,293 kg/m3 at 273 K (0 C) and 101,3 kPa: where NOx conc, COconc, HCconc (3) are the average concentrations (ppm) in the raw exhaust gas, as determined in Section 4.1. If, optionally, the gaseous emissions are determined with a full flow dilution system, the following formulae shall be applied: where NOx conc, COconc, HCconc (3) are the average background corrected concentrations (ppm) of each mode in the diluted exhaust gas, as determined in Annex III, Appendix 2, Section 4.3.1.1.
← doc__table__390 · All articles · sec_4_4__2__para →
Source: EUR-Lex (Cellar) · retrieved 2026-11-01 · Text as adopted (Official Journal); later amendments are not incorporated in this text.