3.3. Structural data on electricity and heat generation
The capacity should be reported at 31 December of the relevant reported year. Includes electrical capacity of both electricity (only) and CHP plants. The net maximum electrical capacity is the sum of the net maximum capacities of all stations taken individually throughout a given period of operation. The period of operation assumed for present purposes is continuous running: in practice 15 hours or more per day. The net maximum capacity is the maximum power assumed to be solely active power that can be supplied, continuously, with all plant running, at the point of outlet to the network. The peak load is defined as the highest value of the power absorbed or supplied by a network or combination of networks within the country. The following quantities must be declared only for the network: 1. Total 2. Nuclear 3. Hydro 3.1. Of which: pumped storage 4. Geothermal 5. Solar 6. Tide, wave, ocean 7. Wind 8. Combustible fuels 8.1. Of which: steam 8.2. Of which: internal combustion 8.3. Of which: gas turbine 8.4. Of which: combined cycle 8.5. Of which: other To be specified if declared. 9. Peak load 10. Available capacity at time of peak 11. Date and time of peak load occurrence Net maximum electrical capacity of combustible fuels must be declared for both main activity producers and autoproducers, and separately for each type of single-fired or multi-fired plant mentioned in the next table. Indications on which type of fuel is used as primary and alternate fuels must be added for all cases of multi-fired plants. 1. Single fuel fired: 1.1. Fired with coal or coal products Includes coke oven gas, blast furnace and oxygen steel furnace gas capacity. 1.2. Fired with liquid fuels Includes refinery gas capacity. 1.3. Fired with natural gas Includes gasworks gas capacity. 1.4. Fired with peat 1.5. Fired with combustible renewables and wastes 2. Multi-fired, solids and liquids 3. Multi-fired, solids and natural gas 4. Multi-fired, liquids and natural gas 5. Multi-fired, solids, liquids and natural gas Multi-fired systems include only units which can burn more than one fuel type on a continuous basis. Stations which have separate units using different fuels should be divided into the appropriate single-fuel categories.
← anx_B__cpt_3__cpt_2__cpt_6__point_4__table_1__row_34__cell_1 · All articles · 3.3.1. Installierte elektrische Leistung und Spitzenlast →
Source: EUR-Lex (Cellar) · retrieved 2026-10-31 · Text as adopted (Official Journal); later amendments are not incorporated in this text.