(b)
Ambient temperature pressure cycle test: the purpose of the test is to provide evidence that the hydrogen container is capable of resisting high variations of pressure. In order to prove this, pressure cycles are carried out on the container until a failure occurs or until a specified number of cycles is reached by increasing and decreasing the pressure to a specified value. The containers must not fail before reaching a specified number of cycles. The number of cycles to failure, along with the location and description of the failure, must be documented. The manufacturer must keep the results throughout the service life of the container.