MEASUREMENTS

Measurements of the power consumption referred to in Annex I, Part 1 shall fulfil all of the following conditions: Measurements shall be made using a reliable, accurate and reproducible measurement procedure, which takes into account the generally recognised state of the art measurement methods. Conditions of televisions for measuring the on-mode power consumption: Television sets without forced menu: the power consumption referred to in points 1 and 2 shall be measured in the on-mode condition of the television as delivered by the manufacturer, that is, the brightness controls of the television shall be in the position adjusted by the manufacturer for the end user. Television sets with forced menu: the power consumption referred to in points 1 and 2 shall be measured in the ‘home-mode’ condition. Television monitors without forced menu: the television monitor shall be connected to an appropriate tuner. The power consumption referred to in points 1 and 2 shall be measured in the on-mode condition of the television as delivered by the manufacturer, that is, the brightness controls of the television monitor shall be in the position adjusted by the manufacturer for the end user. The power consumption of the tuner is not relevant for the measurements of on-mode power consumption of the television monitor. Television monitors with forced menu: the television monitor shall be connected to an appropriate tuner. The power consumption referred to in points 1 and 2 shall be established in the ‘home mode’ condition. General conditions: Measurements shall be made at an ambient temperature of 23 °C +/– 5 °C. Measurements shall be made using a dynamic broadcast-content video signal representing typical broadcast TV content. The measurement shall be the average power consumed over 10 consecutive minutes. Measurements shall be made after the television has been in the off-mode for a minimum of 1 hour immediately followed by a minimum of 1 hour in the on-mode and shall be completed before a maximum of 3 hours in on-mode. The relevant video signal shall be displayed during the entire on-mode duration. For televisions that are known to stabilise within 1 hour, these durations may be reduced if the resulting measurement can be shown to be within 2 % of the results that would otherwise be achieved using the durations described here. Measurements shall be made with an uncertainty of less than or equal to 2 % at the 95 % confidence level. Measurements shall be made with the Automatic Brightness Control function, if such a function exists, made inactive. If the Automatic Brightness Control function exitsts and cannot be made inactive, then the measurements shall be performed with the light entering directly into the ambient light sensor at a level of 300 lux, or more. Measurements of the power consumption referred to in Annex I, Part 2 shall fulfil all of the following conditions: The power consumption referred to in points 1(a), 1(b), 2(a) and 2(b) shall be measured by a reliable, accurate and reproducible measurement procedure, which takes into account the generally recognised state of the art measurement methods. Measurements of power of 0,50 Watt or greater shall be made with an uncertainty of less than or equal to 2 % at the 95 % confidence level. Measurements of power of less than 0,50 Watt shall be made with an uncertainty of less than or equal to 0,01 Watt at the 95 % confidence level. Measurements of the peak luminance referred to in Annex I, Part 4 shall fulfil all of the following conditions: Measurements shall be made using a reliable, accurate and reproducible measurement procedure, which takes into account the generally recognised state of the art measurement methods. Measurements of peak luminance shall be made with a luminance meter, detecting that portion of the screen exhibiting a full (100 %) white image, which is part of a ‘full screen test’ test pattern that does not exceed the average picture level (APL) point where any power limiting occurs in the display luminance drive system. Measurements of luminance ratio shall be made without disturbing the luminance meter’s detection point on the display whilst switching between the conditions referred to in Annex I, Part 4.

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-26 · Text as adopted (Official Journal); later amendments are not incorporated in this text.