3. Measurements of peak luminance

Measurements of the peak luminance referred to in Annex I, Part 4 shall fulfil all of the following conditions: Measurements shall be made using a reliable, accurate and reproducible measurement procedure, which takes into account the generally recognised state of the art measurement methods. Measurements of peak luminance shall be made with a luminance meter, detecting that portion of the screen exhibiting a full (100 %) white image, which is part of a ‘full screen test’ test pattern that does not exceed the average picture level (APL) point where any power limiting occurs in the display luminance drive system. Measurements of luminance ratio shall be made without disturbing the luminance meter’s detection point on the display whilst switching between the conditions referred to in Annex I, Part 4.