2. Accuracy classes
2.1. The following accuracy classes have been defined: I special II high III medium IIII ordinary The specifications of these classes are given in Table 1. Table 1 Accuracy classes Class Verification scale interval (e) Minimum capacity (Min) Number of verification scale intervals n((Max)(e)) minimum value minimum value maximum value I 0,001 g ≤ e 100 e 50000 — II 0,001 g ≤ e ≤ 0,05 g 20 e 100 100000 0,1 g ≤ e 50 e 5000 100000 III 0,1 g ≤ e ≤ 2 g 20 e 100 10000 5 g ≤ e 20 e 500 10000 IIII 5 g ≤ e 10 e 100 1000 The minimum capacity is reduced to 5 e for instruments in classes II and III for determining a conveying tariff. The actual scale interval (d) and the verification scale interval (e) shall be in the form: 1 × 10^(k), 2 × 10^(k), or 5 × 10^(k) mass units, k being any integer or zero. For all instruments other than those with auxiliary indicating devices: d = e. For instruments with auxiliary indicating devices the following conditions apply: e1 10k g; d < e ≤ 10 d. Those conditions do not apply for instruments of class I with d < 10^(–4) g, for which e = 10^(–3) g.
← anx_I__cpt_1__cpt_2__cpt_1__text_3 · All articles · anx_I__cpt_1__cpt_2__cpt_2__cpt_1 →
Source: EUR-Lex (Cellar) · retrieved 2026-11-05 · Text as adopted (Official Journal); later amendments are not incorporated in this text.