2.1. The following accuracy classes have been defined: I special II high III medium IIII ordinary The specifications of these classes are given in Table 1. Table 1 Accuracy classes Class Verification scale interval (e) Minimum capacity (Min) Number of verification scale intervals n((Max)(e)) minimum value minimum value maximum value I 0,001 g ≤ e 100 e 50000 — II 0,001 g ≤ e ≤ 0,05 g 20 e 100 100000 0,1 g ≤ e 50 e 5000 100000 III 0,1 g ≤ e ≤ 2 g 20 e 100 10000 5 g ≤ e 20 e 500 10000 IIII 5 g ≤ e 10 e 100 1000 The minimum capacity is reduced to 5 e for instruments in classes II and III for determining a conveying tariff.