3.1.
For each of the fractions measured, the maximum error value permitted under rated operating conditions according to point 1.1 of Annex I is the greater of the two values shown in Table 2. Absolute values are expressed in % vol or ppm vol, percentage values are percent of the true value. Table 2 MPEs Parameter Class 0 Class I CO fraction ± 0,03 % vol ± 5 % ± 0,06 % vol ± 5 % CO_(2) fraction ± 0,5 % vol ±5 % ± 0,5 % vol ± 5 % HC fraction ± 10 ppm vol ± 5 % ± 12 ppm vol ± 5 % O_(2) fraction ± 0,1 % vol ± 5 % ± 0,1 % vol ± 5 %