(2)
If the equipment has more than one type of network port, for each type of network port the following procedure is repeated. If two or more network ports of a type are available, one port is chosen randomly for each type of network port and that port is connected to the appropriate network complying with the port’s maximum specification. If for a certain type of network port only one port is available, that port is connected to the appropriate network complying with the port’s maximum specification. Wired network ports not used shall be disconnected and wireless ports not used shall be deactivated. The tested unit is switched on. The device that provides the remotely initiated trigger that will reactivate the tested unit is connected to the appropriate network, switched on, and ready to provide the trigger when required to. Once the tested unit is switched on and working properly, it is allowed to go into networked standby and the power consumption is measured. Then the appropriate trigger is given to the unit through the network port and a check is made on whether the equipment is reactivated. If one physical network port is shared by two or more types of (logical) network ports, that procedure is repeated for each type of logical network port, with the other logical network ports being logical-disconnected.